Cat 12 H Grader Manual
06.01.2021by admin
Cat 12 H Grader Manual Rating: 6,3/10 7830 reviews
Caterpillar Motor Graders 12H, 140H, 160H workshop service repair manual includes:. Numbered table of contents easy to use so that you can find the information you need fast. Detailed sub-steps expand on repair procedure information. Numbered instructions guide you through every repair procedure step by step.
Usage:
120H124Use the Caterpillar Monitoring System or use the Caterpillar Electronic Technician in order to determine the diagnostic codes for the power train ECM. After determining the diagnostic codes, refer to the corresponding test procedure for more information. Perform the procedure that corresponds to the diagnostic code (CID and FMI). The following table is a list of possible diagnostic codes for the ECM.
- CATERPILLAR Motor Graders Parts Catalogs, Service (workshop) Manuals, Operation and Maintenance Manuals in PDF format. Very important remark: The CAT equipment prefix (first three figures and numbers in serial number) is absolutely necessary information for correct engine identification. But your additional information (full serial number, arrangement number, where the engine is installed etc.
- Operators Manual (OPT) - The operators manual (a.k.a. Owners manual) is the book that came OEM from the manufacturer when the Caterpillar 12 Grader was purchased. It gives the owner/operator instructions, shift patterns, capacities (anti freeze, crankcase, oil, hydraulic, etc.).
Cat 12h Grader Manual
Diagnostic Codes For The Power Train ECM (MID 081) (1) | |
---|---|
For troubleshooting, see the procedure with the same diagnostic code. | |
CID/FMI | Description |
CID 0168 Electrical System Voltage | |
FMI 01 | 'Below normal range' |
CID 0177 Temperature Sensor (Transmission Oil) | |
FMI 03 | 'Voltage above normal or shorted high' |
FMI 04 | 'Voltage below normal' |
CID 0248 Cat Data Link | |
FMI 02 | 'Incorrect signal' |
CID 0268 Programmable Parameter | |
FMI 02 | 'Incorrect signal' |
CID 0444 Magnetic Switch (Start Relay) | |
FMI 03 | 'Voltage above normal or shorted high' |
FMI 05 | 'Current below normal' |
FMI 06 | 'Current above normal' |
CID 0520 Configuration (Transmission) | |
FMI 02 | 'Incorrect signal' |
CID 0562 Caterpillar Monitoring System | |
FMI 09 | 'Abnormal update' |
CID 0573 Position Sensor (Clutch Pedal) | |
FMI 03 | 'Voltage above normal or shorted high' |
FMI 04 | 'Voltage below normal' |
FMI 13 | 'Out of calibration' |
CID 0585 Speed Sensor (Transmission Output) (No. 1) | |
FMI 02 | 'Incorrect signal' |
CID 0637 Backup Alarm | |
FMI 06 | 'Current above normal' |
CID 0668 Transmission Control (Shift Lever) | |
FMI 02 | 'Incorrect signal' |
FMI 03 | 'Voltage above normal' |
CID 0669 Speed Sensor (Transmission Input) | |
FMI 02 | 'Incorrect signal' |
CID 0673 Speed Sensor (Transmission Output) (No. 2) | |
FMI 02 | 'Incorrect signal' |
CID 0688 Solenoid Valve (Dual Horsepower) | |
FMI 06 | 'Current above normal' |
CID 0868 Indicator Lamp (Automatic shift) | |
FMI 03 | 'Voltage above normal' |
FMI 05 | 'Current below normal' |
FMI 06 | 'Current above normal' |
CID 1401 Solenoid Valve (Forward High) | |
FMI 03 | 'Voltage above normal' |
FMI 05 | 'Current below normal' |
FMI 06 | 'Current above normal' |
FMI 13 | 'Out of Calibration' |
CID 1402 Solenoid Valve (Forward Low) | |
FMI 03 | 'Voltage above normal' |
FMI 05 | 'Current below normal' |
FMI 06 | 'Current above normal' |
FMI 13 | 'Out of Calibration' |
CID 1403 Solenoid Valve (Reverse) | |
FMI 03 | 'Voltage above normal' |
FMI 05 | 'Current below normal' |
FMI 06 | 'Current above normal' |
FMI 13 | 'Out of Calibration' |
CID 1404 Solenoid Valve (Speed Clutch) (No. 2) | |
FMI 03 | 'Voltage above normal' |
FMI 05 | 'Current below normal' |
FMI 06 | 'Current above normal' |
CID 1405 Solenoid Valve (Speed Clutch) (No. 3) | |
FMI 03 | 'Voltage above normal' |
FMI 05 | 'Current below normal' |
FMI 06 | 'Current above normal' |
CID 1406 Solenoid Valve (Speed Clutch) (No. 1) | |
FMI 03 | 'Voltage above normal' |
FMI 05 | 'Current below normal' |
FMI 06 | 'Current above normal' |
CID 1407 Solenoid Valve (Low Range) | |
FMI 03 | 'Voltage above normal' |
FMI 05 | 'Current below normal' |
FMI 06 | 'Current above normal' |
CID 1408 Solenoid Valve (High Range) | |
FMI 03 | 'Voltage above normal' |
FMI 05 | 'Current below normal' |
FMI 06 | 'Current above normal' |
CID 1484 Limit Switch (Clutch Pedal) | |
FMI 03 | 'Voltage above normal' |
FMI 04 | 'Voltage below normal' |
CID 1580 Indicator Lamp (Transmission Filter Bypass ) | |
FMI 03 | 'Voltage above normal' |
FMI 05 | 'Current below normal' |
FMI 06 | 'Current above normal' |
Show/hide table
( 1 ) | For the Power Train ECM, the MID is 081. This table pertains only to diagnostic codes with a MID of 081. |
Note: This table shows the diagnostic codes for the power train ECM only. The diagnostic codes for the ECM are shown on the display area of the Caterpillar Monitoring System. The information of the diagnostic code for the ECM is transferred via the Cat data link to the Caterpillar Monitoring System. This diagnostic information is shown when the Caterpillar Monitoring System is in the service mode. The module identifier (MID) tells the service person the ECM that is sending the diagnostic code. The MID for the power train ECM is 081. This Service Manual is used for diagnostic codes with the MID 081. The Electrical System Schematic shows the module identifier (MID) codes of any other electronic controls on a machine. Information for electronic troubleshooting of the diagnostic codes (MID is not 081) can be found in the service manual for that system.
Cat 12h Grader For Sale
Paheli full movie mp4 google drive.
INSTANT DOWNLOAD (add to cart)
Complete workshop & service manual with electrical wiring diagrams for Caterpillar 12H, 140H & 160H Motor Graders. It’s the same service manual used by dealers that guaranteed to be fully functional and intact without any missing page.
Caterpillar 12H Motor Grader - RitchieSpecs
This Caterpillar 12H, 140H & 160H Motor Graders service & repair manual (including maintenance, overhaul, disassembling & assembling, adjustment, tune-up, operation, inspecting, diagnostic & troubleshooting…) is divided into different sections. Each section covers a specific component or system with detailed illustrations. A table of contents is placed at the beginning of each section. Pages are easily found by category, and each page is expandable for great detail. The printer-ready PDF documents work like a charm on all kinds of devices. Belly dance bvh files for poser.
FILELIST:
RENR1417 – Systems Operation (120H, 12H, 135H, 140H, 143H, 160H & 163H Motor Graders Air System & Brakes)
RENR1417 – Testing & Adjusting (120H, 12H, 135H, 140H, 143H, 160H & 163H Motor Graders Air System & Brakes)
RENR1418 – Specifications (12H, 140H & 160H Motor Graders Air System & Brakes)
RENR1430 – Schematic (12H, 140H & 160H Motor Grader Hydraulic System)
RENR1436 – Schematic (12H, 140H & 160H Motor Graders (Standard Version) Electrical System)
RENR9540 – Schematic (12H, 140H &160H Motor Grader Electrical System (for SN 4ER1136-UP, 5HM3000-UP, 2FM909-UP) All Other SN 1_UP)
SENR6998 – Specifications (12H, 140H, 143H, 160H & 163H Motor Graders Power Train)
SENR8503 – Systems Operation (120H, 12H, 135H, 140H, 143H, 160H & 163H Motor Graders Power Train)
SENR8503 – Testing & Adjusting (120H, 12H, 135H, 140H, 143H, 160H & 163H Motor Graders Power Train)
SENR8503 – Troubleshooting (120H, 12H, 135H, 140H, 143H, 160H & 163H Motor Graders Power Train)
SENR8539 – Disassembly & Assembly (12H, 140H & 160H Motor Graders Engine Supplement)
SENR8548 – Disassembly & Assembly (12H, 140H & 160H Motor Graders Power Train)
SENR8549 – Disassembly & Assembly (12H, 140H & 160H Motor Graders Machine Systems)
SENR8571 – Schematic (12H, 140H &160H Motor Grader Standard Version Hydraulic System (for SNs 2FM1-399, 5HM1-1149, 8JM1-279, 9JM1-349, 4ER1-499) All Other SN 1-UP)
SENR8623 – Specifications (12H, 140H & 160H Motor Graders Hydraulic & Steering System)
SENR8669 – Specifications (12H, 140H & 160H Standard Version Motor Graders Air System…)
SENR9149 – Schematic (12H, 140H &160H Motor Grader Standard Version Electrical System (for SN 4ER500-1135, 8JM280-UP, 5HM1150-2999, 9JM350-UP, 2FM400-908)
SENR9156 – Specifications (12H, 140H, 143H, 160H & 163H Motor Graders Power Train)
SENR9159 – Systems Operation (120H, 12H, 135H, 140H, 143H, 160H & 163H Motor Graders)
SENR9159 – Testing & Adjusting (120H, 12H, 135H, 140H, 143H, 160H & 163H Motor Graders)
SENR9178 – Specifications (12H, 140H, 143H, 160H & 163H Motor Graders Hydraulic and Steering System)
SENR9186 – Systems Operation (120H, 12H, 135H, 140H, 143H, 160H & 163H Motor Graders Hydraulic & Steering System)
SENR9186 – Testing & Adjusting (120H, 12H, 135H, 140H, 143H, 160H & 163H Motor Graders Hydraulic & Steering System)
SENR9186 – Troubleshooting (120H, 12H, 135H, 140H, 143H, 160H & 163H Motor Graders Hydraulic & Steering System)
RENR9540 – Schematic (12H, 140H & 160H Motor Grader Electrical System).pdf
RENR9571 – Schematic (12H, 140H & 160H Motor Graders Standard Versions Hydraulic System).pdf
SENR8518 – Systems Operation (120H,135H,12H,140H,160H,143H,163H MG HYD System & Steering).pdf
SENR8518 – Testing & Adjusting (120H,135H,12H,140H,160H,143H,163H MG HYD System & Steering).pdf
SENR8670 – Systems Operation (120H, 135H, 12H, 140H & 160H Standard Version Motor Graders).pdf
SENR8670 – Testing & Adjusting (120H, 135H, 12H, 140H & 160H Standard Version Motor Graders).pdf
EXCERPT:
11. Remove carriage assembly (2) from the ripper assembly. The weight of carriage assembly (2) is 500 kg (1100 lb).
Illustration 6
12. Position a suitable lifting device to link assembly (7). Remove bolts (10) and the locknuts from mounting pins (12).
13. Remove mounting pins (12) toward the center of the ripper until shims (11) and link assembly (7) are free of the ripper mounting bracket.
14. Remove link assembly (7) from the ripper mounting bracket. The weight of link assembly (7) is 132 kg (290 lb).
…
Category: Manual